Pasted Graphic 5 page0_1 page2_3

Standards  Architectonic/construction part
Foundations

Foundations
reinforced concrete strip foundations; reinforced concrete bed slab

Hydroinsulation
against water and ground dampness - PVC sheeting ALKORPLAN 35 034

Thermal insulation for the foundations
40mm extruded polystyrene

External cladding
Exterior facade paint
facade paint (Caparol or similar)

Brickwork
365mm Liapor SL over a thermally insulated mortar

Plumbing elements and sheeting
plumbing elements and sheeting from Titanzink

Windows
wooden, three-layer laminated (pine) 'Euro profile', surface finish: spruce varnish; glazing thermal insulation U=1,1 W/m˛K

Street bays
ceiling: a single reinforced concrete slab.walls: 365mm Liapor SL over a thermally insulated mortar, lined with a CETRIS cladding pane(wood imitation) - golden saffron

External plaster
lime plaster

Internal plaster
lime plaster

Thermal insulation for the external cladding
non-insulated facade (insulation standard fulfilled through use of bricks)

Internal walls and partition walls
Internal partitioning walls between apartments
wall thickness 175mm; Liapor M 175 breezeblocks on VPC mortarwall thickness 175mm solid concrete

Internal walls and partitions
wall thickness 175mm; Liapor M 175 breezeblocks on VPC mortar

wall thickness 175mm solid concrete
wall thickness 175mm; Liapor M 75 breezeblocks on VPC mortar

Internal paintwork
single colours, light, wear resistant

Entrance doors
to individual apartments - Sapeli Elegant, lined door frames

Interior doors
Sapeli Elegant, Sapeli door frames

Internal plaster
Lime plaster


Ceiling construction
Ceiling construction
reinforced concrete single slabs without joists

Internal stairways
monolithic reinforced concrete

Plaster
Lime plaster (toilets and bathrooms with plasterboard false ceilings)

Floors
Floor load-bearing structure
contact layer (depending on room - floating floor or ceramic tiles) impact insulation 3mmself-levelling surface 2mm keramzit concrete screed floor cover 105mm reinforced concrete ceiling construction 280 mm

Thermal and impact insulation
impact insulation Mirelon 3mm thermal insulation Keramzit concrete screed floor cover 105mm thermal floor insulation over unheated spaces extruded polystyrene STYRODUR 3035 100mm

Garage door
Gate construction
remote control, folds under ceiling

Surface finish
exterior paint (grey)

Surface finishes in common areas
Corridors
exposed concrete

Garage
exposed concrete

Stairways
Wear resistant surface (REBAL FLOW)

Hand rails
rust-free

Lift
standard finish including equipment for handicapped users

Standard fixtures and fittings in apartments
Fixtures and fittings:
• Ideal Standard and Ravak
• Ideal Standard toilet
• tiled Ravak bath or Ravak shower corner
• bidet
• inbuilt washbasin

Heating
central gas boiler room for heating water and hot water

Floors in apartments
Floating floors
• Bathroom
• Study
• Corridor
• Living room
Ceramic tiles
• Bathroom ,WC (with underfloor electric heating)
• Kitchen corner
• Hall
Satellite, TV, radio and telephone connections in all apartments.

Pasted Graphic 1